Reader Comments

The Railway Technical Website

by Anitra Cardwell (2025-09-07)

 |  Post Reply

gauge gauges meter meters volts amps amperes electiricty measuring measure dials electrical electric Have you ever seen that when a toy's motor gets highly regarded it smells? Heat breaks down all types of insulation ultimately, and in a motor winding when the insulation will get weak sufficient two wires aspect by side will short, this causes and arc and the system burns out. If you take a small motor that you don't care about you possibly can intentionally burn it out to see what happens to the windings. These particular horns have a small air stress tube hooked up which, if the pressure is lost, will trigger the pan to lower robotically and so scale back the attainable wire damage. The subsections will be joined via particular high speed section switches. At such locations, like terminal stations, "section switches" are provided. After all there are exceptions and we'll see a few of them later. See how motor wire is packed and wound into modern induction motors in our video right here. Learn extra about the whole subject of electrical insulation on our web page here. A extra environment friendly system of AC electrification is understood because the auto transformer system. To attain this, the availability sub-station transformer is supplied with a centre tap secondary winding at 50 kV (set to fifty five kV for the maximum restrict of contact wire voltage of 27.5 kV).



there is no spoon rust cobwebs dirst bright The contact wire is grooved to allow a clip to be fastened on the highest aspect (Figure 7). The clip is used to attach the dropper wire. The steel middle is used simply for strength, to carry the wire over lengthy spans. Aluminum wrapped around a steel center wire is utilized in power transmission because the aluminum is cheaper than copper and would not corrode. Of course, it needed a heavier transmission medium, a third rail or a thick wire, to hold the facility and it lost a fair quantity of voltage as the distance between supply connections increased. Up to 3000 volts overhead is utilized by DC important line methods (e.g., components of France, Belgium and Italy) but beneath 1500 volts, a 3rd rail can be utilized. DC, alternatively was the popular choice for shorter traces, city systems and tramways. To beat this drawback, many programs used booster transformers.



More fashionable techniques use a single arm pantograph - really simply half of the unique form - a neater trying design (photograph above). At the other end of the scale, a tram depot could have only a single wire hung straight from insulated supports. The insulation and clearances may still be designed for 25 kV AC only. Traditional rubber or polymer insulation would make the wire diameter thicker, what is electric cable that is one purpose why outdated electric motors had been greater and heavier than modern motors of the identical horsepower. This was nicely understood within the late 19th Century and was one of many the explanation why London’s Underground railways adopted a completely insulated DC system with a separate unfavourable return rail as well as a optimistic rail - the 4-rail system. They're connected to the feeder station by a return conductor cable hung from the masts so that it is roughly the identical distance from the observe as the overhead line. The return conductor is connected to the operating rail at intervals to parallel the return cable and rails. There needs to be a whole circuit, from the source of the power out to the consuming item (light bulb, cooking stove or train) and again to the source, so a return conductor is required for our railway.



Figure 12: Russian video of a pantograph being damaged by an overhead wire out of place. Now use the charts above to figure out what sort of wire it's, what it's made from, and record the uses for every. We have already talked about the issue (above) of a wave being formed in the wire by a pantograph shifting at high velocity. It additionally signifies that, if trains are stopped and should be evacuated, the current has to be turned off earlier than passengers could be allowed to wander the track. Originally, pantographs were just that, a diamond-formed "pantograph" with the contact head at the highest. The contact wire tension shall be within the region of 2 tonnes. The weights and pulley system is designed to keep up contact wire tension. The contact wire has to be held in tension horizontally and pulled laterally to negotiate curves within the track. The tension of the wire is maintained by weights suspended at each finish of its length. The wire have to be able to hold the present (several thousand amps), stay consistent with the route, withstand wind (in Hong Kong typhoon winds can attain 200 km/h), excessive chilly and heat and other hostile weather situations.



Add comment