Since the current may have been switched off to cease an arc or because of a short circuit, it's important that the practice doesn't join the dead section to the live part by passing over the hole and permitting its busline to bridge the gap. It can be summarised simply as AC for lengthy distance and DC for short distance. The wire have to be ready to hold the present (a number of thousand amps), stay in keeping with the route, withstand wind (in Hong Kong typhoon winds can attain 200 km/h), extreme cold and heat and different hostile weather situations. Current is collected from overhead traces by pantographs. If a communications cable is laid alongside rails carrying the return current of the overhead line supply, it might have unequal voltages induced in it. What about the electrical return? There has to be an entire circuit, from the supply of the power out to the consuming merchandise (gentle bulb, cooking stove or prepare) and back to the source, so a return conductor is needed for our railway. These are turned downwards to scale back the risk of the pantograph being hooked excessive of the contact wire as the prepare strikes alongside.
Overhead traces are usually fed in sections like third rail methods, but AC overhead sections are normally for much longer. This was properly understood in the late 19th Century and was one of the explanation why London’s Underground railways adopted a totally insulated DC system with a separate destructive return rail in addition to a optimistic rail - the 4-rail system. The ability circuit on the practice is accomplished by connecting the return to brushes rubbing on the axle ends. The rear automobile is equipped via a 25 kV cable operating the length of the practice. The French TGV (High Speed Train) formation has a energy car at each finish of the train however solely runs with one pantograph raised under the high velocity 25 kV AC strains. The subsections may be joined via particular excessive velocity part switches. Over lengthy distances the unequal voltages can characterize a security hazard. That is about its limit for velocity and has solely spread over such a large space for historic causes.
We now have already talked about the problem (above) of a wave being formed in the wire by a pantograph shifting at high pace. Generally, it’s a query of what type of railway you could have. You just need to put the best kind of control system between the availability and the motor and it'll work. Aside from only requiring a simple management system for the motors, the smaller size of city operations meant that trains had been usually lighter and wanted less energy. The weights and pulley system is designed to maintain contact wire tension. The tension of the wire is maintained by weights suspended at each finish of its length. The contact strips of the pantograph are supported by a lightweight transverse body which has "horns" at every end. At the opposite finish of the dimensions, a tram depot might have just a single wire hung straight from insulated supports. Overhead catenary programs, known as "catenary" from the curve formed by the supporting cable, have a posh geometry, nowadays usually designed by pc. These special horns have a small air pressure tube hooked up which, if the pressure is lost, will trigger the pan to decrease mechanically and so reduce the potential wire harm.
Pantograph contact is maintained either by spring or air pressure. As a pantograph passes alongside it, the wire might be seen to rise and fall. At varied factors alongside the road, there will probably be places the place trains might be quickly remoted electrically from the provision system. The auto transformer system permits substations to be additional apart with out voltage drop. Figure 11: A schematic showing the preparations for 25kV AC electrification techniques utilizing booster transformers (higher drawing) and the auto transformer system (decrease drawing). To attain this, the availability sub-station transformer is provided with a centre tap secondary winding at 50 kV (set to 55 kV for the maximum restrict of contact wire voltage of 27.5 kV). Figure 6: Diagram showing a 3rd rail DC power supply system and how present rail gaps are provided where the substations feed the line. Third rail routes need particular protection to be completely secure.
The Railway Technical Website
by Alicia Rister (2025-08-20)
| Post Reply
We now have already talked about the problem (above) of a wave being formed in the wire by a pantograph shifting at high pace. Generally, it’s a query of what type of railway you could have. You just need to put the best kind of control system between the availability and the motor and it'll work. Aside from only requiring a simple management system for the motors, the smaller size of city operations meant that trains had been usually lighter and wanted less energy. The weights and pulley system is designed to maintain contact wire tension. The tension of the wire is maintained by weights suspended at each finish of its length. The contact strips of the pantograph are supported by a lightweight transverse body which has "horns" at every end. At the opposite finish of the dimensions, a tram depot might have just a single wire hung straight from insulated supports. Overhead catenary programs, known as "catenary" from the curve formed by the supporting cable, have a posh geometry, nowadays usually designed by pc. These special horns have a small air pressure tube hooked up which, if the pressure is lost, will trigger the pan to decrease mechanically and so reduce the potential wire harm.
Pantograph contact is maintained either by spring or air pressure. As a pantograph passes alongside it, the wire might be seen to rise and fall. At varied factors alongside the road, there will probably be places the place trains might be quickly remoted electrically from the provision system. The auto transformer system permits substations to be additional apart with out voltage drop. Figure 11: A schematic showing the preparations for 25kV AC electrification techniques utilizing booster transformers (higher drawing) and the auto transformer system (decrease drawing). To attain this, the availability sub-station transformer is provided with a centre tap secondary winding at 50 kV (set to 55 kV for the maximum restrict of contact wire voltage of 27.5 kV). Figure 6: Diagram showing a 3rd rail DC power supply system and how present rail gaps are provided where the substations feed the line. Third rail routes need particular protection to be completely secure.
Here is more info about what is electric cable look at the website.
Add comment